Hydraulic drive operation, Drive operational requirements, Hydraulic system – Great Plains 3N-4025P Operator Manual User Manual

Page 42: Electrical system, Tractor hookup, Hydraulics, Electrical, Hydraulic system: electrical system, Hydraulics: electrical

Advertising
background image

196-538M

Table of Contents

Index

2014-01-29

38

3N-40P

Table of Contents

Index

Great Plains Manufacturing, Inc.

Hydraulic Drive Operation

Seeding rate on the 3N-40P family is controlled entirely
seed meter wheel selection, and by the seed monitor
and the hydraulic drive. This section of the manual
describes monitor setup and operation.

Drive Operational Requirements

Hydraulic System:

Closed Center, pressure compensated or load sensed
systems only

Drive will not operate on Open-Center hydraulic systems

Electrical System:

Tractor Hookup

Hydraulics:

1.

Connect pressure hose (P) to retraction outlet

2.

Connect motor return hose (T) to motor return port (if
available) or to extension outlet.

3.

Set flow rate at maximum required flow of 13 gpm.

4.

If tractor is equipped with electro-hydraulic valves,
set timer to “constant” flow.

Electrical:

Refer to Figure 38
Power must be connected directly to the battery. Make
sure that eyelets are properly connected (red to positive,
black to negative). Connect female socket to power port
adapter.

Disconnect all cables and remove VER-21568 Ext. Control
module before welding on drill. See page 137.

Minimum Hydraulic Pressure

2250 psi

Maximum Hydraulic Pressure

3000 psi

Maximum Required Flow

8.5 gpm

Voltage

12 volts DC

Current

4 amperes

High Pressure Fluid Hazard: Escaping fluid under pressure
can penetrate skin, causing serious injury. Avoid the hazard by
relieving pressure before disconnecting hydraulic lines. Use a
piece of paper or cardboard, NOT BODY PARTS, to check for
leaks. Wear protective gloves and safety glasses or goggles
when working with hydraulic systems. If an accident occurs,
seek immediate medical attention from a physician familiar
with this type of injury.

Moving Chain Hazard: Return hydraulic drive circuit lever to
Neutral before exiting tractor cab. Unexpected drive rotation
can cause serious injury.

22715

Figure 38

Controller Electrical Connection

22714

Advertising