Edge Lighting TruLine .5A, 24VDC - Plaster-In LED System User Manual

Page 13

Advertising
background image

13

35

NOT INSTALLED

CORRECTLY

35:

Snap the lens back onto the channel sections. Ensure lens is fully seated.

35

Z17

Section Five: Zig Zag Installation

CORRECT

JUNCTION
BOX

1

MOUNTING
BRACKET

PHILLIPS
SCREW

ADJUSTABLE
MOUNTING BAR

1: Mount each adjustable mounting bar to one side of the
junction box and secure them with the mounting brackets
and two Phillips screws provided.

2: Place the lips on the adjustable mounting bars against
the studs. Secure the adjustable bars to the studs with
the eight #8 screws.

3: Install conduit (if required by local electrial code) and run
low-voltage power wires to the junction box.

NOTE:

The adjustable mounting bars mount to studs that

are spaced 13" to 24" apart.

INSTALLATION
DIRECTION

ADJUSTABLE
MOUNTING BAR

STUD

#8 SCREW

2

3

JUNCTION
BOX

CONDUIT W/
LOW-VOLTAGE WIRES

6" FIXED
JAB SAW

4: Cut a section of drywall using a 6" fixed jab saw or other
appropriate tool to expose the mounting plate area.

4

5: Insert the joiner bars halfway into the channel trap door
frame. Tighten the two #4-40 set screws on each joiner bar
with a 0.05" Allen wrench.

6: Slide the other section of channel onto the joining bars and
tighten the remaining #4-40 set screws with a 0.05" Allen
wrench.

5

6

JOINER
BAR

TRAP DOOR
FRAME

Z18

Z19

Z20

Z21

Advertising