Qr s – Edge Lighting TruLine .5A, 24VDC - Plaster-In LED System User Manual

Page 6

Advertising
background image

26: Remove the blue contractor’s tape from the inside of the
channel. Clean the channel surface with alcohol to remove
any dust or debris before continuing.

27: Attach the trap door to the junction box using the #6-32 screw.

TRAP DOOR

29: Firmly press down the adhesive portion of the soft strip onto
the channel surface while removing the rest of the backing,
making sure there are no air bubbles that can cause surface
irregularities.

P

6

#6-32
SCREW

27

26

28: Carefully remove the backing from the LED soft strip, making
sure not to remove the tape from the soft strip. Line up the red
wire side of the power connector with the “+24VDC” marking
on the Soft Strip. Push the male connector of the Soft Strip
into the female power connector.

30: If required, trim the soft strip on the dashed cuttable section,
place the excess soft strip inside the take up box (see inset).
Ensure the entire length of the channel is covered with Soft
Strip to avoid unlit areas.

IMPORTANT: Soft strip may not properly adhere to channel
surface unless the channel is cleaned with alcohol prior to
application.

POWER
CONNECTION

PAPER
BACKING

LED STRIP

28

29

LED STRIP

PAPER
BACKING

Q

R

S

30

TAKE-UP
BOX

30

Advertising