6" FIXED
JAB SAW

4: Cut a section of drywall using a 6" fixed jab saw or other
appropriate tool to expose the mounting plate area.

4

E

8: Connect the red power supply (24VDC+) wire to the red
power connector wires with a wire nut.

9: Connect the black power supply (24VDC-) wire to the black
power connector wires with a wire nut.

10: Place the wire nut connections inside junction box.

JUNCTION BOX

8

9

3

5: Determine the desired length of lit installation area and mark on wall. The total installation length cut will need to be 1 3/4" longer
than the desired lit installation area to account for the fixture end caps. (For example, a desired 48" lit area will require a
drywall cut of 49 3/4" inches)
. Mark this length on the wall using the junction box mounting plate and a level as a guide.

6: Cut out the marked area using a "Dremel Multi-Max" or a 6" Fixed Jab Saw.

7: Mark the location of the studs to the drywall for future reference.

D

NOTE: To install channel in a wall without standard-spaced studs, install perforated mounting straps every 32" behind drywall
and secure using two drywall screws. Mark the location of any mounting straps to the drywall.

MARKING

STUD

MOUNTING
STRAP

1.05"

5

6

6

7

DESIRED LIT LENGTH

0.75"

1.0"

11: Insert the joiner bars halfway into the channel trap door
frame. Tighten the two #4-40 set screws on each joiner bar
with a 0.05" Allen wrench.

12: Slide the other section of channel onto the joining bars and
tighten the remaining #4-40 set screws with a 0.05" Allen
wrench.

F

11

12

CHANNEL

JOINER
BAR

TRAP DOOR
FRAME

TRAP DOOR
FRAME

LENS

13: Snap the lens into the assembled trap door frame and
channel BEFORE cutting to length. This ensures a proper
fit after installation.

13