16: Insert the 90° joiner bracket halfway into the mitered
channel corner. Tighten the two M4 set screws on each
joiner bar with a 1.5MM Allen wrench.

16

Z27

TAKE-UP
BOX

CHANNEL

15: Slide the take-up box onto the non-power channel end and
tighten the M4 set screws with a 1.5MM Allen wrench.

17: Slide the other section of mitered channel onto the 90°
joining brackets and tighten the remaining M4 set screws.

17

90° JOINING
BRACKET

CHANNEL

CHANNEL

Z28

18: Rotate the connector and bend power connection wires
to place the power connector into the end cap insert.

19: Slide the assembled end cap insert and power connector
into the end cap.

18

20: Secure the assembled power connector end cap to the
junction box with the #4-40 screw.

#6 SCREW

CHANNEL

TRAP DOOR

21: Using the mark locations on the drywall, carefully make
a hole to channel using the provided square drill with
counter sink bit.

22: Secure the channel to the studs/mounting straps through
the drywall with the #6 screws using the provided square
recess bit.

23: Secure the Trap Door frame to the junction box with the
#4-40 screw.