Dell PowerVault 50F (Fibre Channel Switch) User Manual

Page 22

Advertising
background image

PowerVault™ 50F Topologies: Dell™ PowerVault™ 50F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

file:///C|/Users/sharon_anand/Desktop/PowerVault/50f_enit/POWER.HTM[3/15/2013 11:31:57 AM]

Figure 2-6 shows a four-switch topology that adds additional paths to the Fabric topology, increasing the
Fabric's reliability, bandwidth, fault tolerance, and connections.

Figure 2-6. Four-Switch Fabric Topology Sample

For example, the shortest path between switch A and switch D would be the direct path AD. If this path were
to fail, the connection would then be automatically routed through either switch B or C with a path of ABD or
ACD.

In Figure 2-6, ports 6 and 7 on the interface module in position 4 of switch A are used for connection to
switch B and switch D. If the interface module failed, traffic to switch B, C, and D would all have to be
rerouted between the interface modules in the third position on switches A and C.

A more robust solution is to have all connections distributed across available interface cards in each switch,
giving an alternate configuration as shown in Figure 2-7.

Figure 2-7. Four-Switch Fabric Topology Sample

If bandwidth or fault tolerance is a concern, each of the paths shown in Figure 2-7 could have a parallel
connection.