Installing the PowerVault™ 50F Switch: Dell™ PowerVault™ 50F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

file:///C|/Users/sharon_anand/Desktop/PowerVault/50f_enit/INSTALL.HTM[3/15/2013 11:31:55 AM]

2. Use a 10-32 x 1/2 inch screw and a 10-32 nut with captive star washer to mount an adjustable bracket

to the other end of the outer slide, as shown in Figure 1-3. Do not completely tighten the screw.

3. Repeat steps 1 and 2 to mount the remaining stationary and adjustable brackets to the second outer

slide.

4. Use four 10-32 x 1/2-inch screws and four tapered washers to mount each outer slide in the rack, as

shown in Figure 1-4.

5. The stationary brackets attach to the rear of the rack. The adjustable brackets attach to the front. The

screws are threaded through the rack and into the top and bottom holes of the brackets, leaving the
middle bracket holes open.

NOTE:

The slides must be mounted within 1 Electronic Industry Association (EIA) unit. The switch takes up 2 EIA

units with the outer bearing slides mounted in the lower of the 2 EIA units.

Figure 1-4. Mounting the Outer Slides and Bezel on the Rack