Dell PowerVault 50F (Fibre Channel Switch) User Manual

Page 61

Advertising
background image

PowerVault™ 50F Commands: Dell™ PowerVault™ 50F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

file:///C|/Users/sharon_anand/Desktop/PowerVault/50f_enit/COMMANDS.HTM[3/15/2013 11:32:02 AM]

Table 7-10. ortLoopbackTest Command Field Descriptions

Field

Description

Diagnostics
Status

The duration of the portLoopbackTest.

port#

The port number.

diags

Possible values include OK, BAD.

state

Possible values include UP (active), DN (inactive).

st0-16

The tested ports. The display shows the diagnostics frames are
transmitted and received and Low Level Interface counts
(LLI_errs).

Central Memory
Status

The central memory status. Possible values include OK,
FAULTY.

Total Diag
Frames Tx

The total diagnostics frames transmitted (Tx) since boot. This
number usually corresponds to the total frames received (Rx), but
may differ because of failure modes.

Total Diag
Frames Rx

The total diagnostics frames received (Rx) since boot. This
number usually corresponds to the total frames transmitted (Tx),
but may differ because of failure modes.

If an error is found, one or more of the following error messages is displayed.

One of the following register names is displayed in the following error message with the message replacing
the term (regname) in the error message.

Enc_in

- Encoding error, inside frame

CRC_err

- Cyclic redundancy check on frame failed

TruncFrm

- Truncated frame

FrmTooLong

- Frame too long

BadEOF

- Bad end of file

Enc_out

- Encoding error, outside frame

BadOrdSet

- Bad symbol on fiber-optic cable

DiscC3

- Discarded Class 3 frames

DIAG-ERRSTAT, 1

Advertising
This manual is related to the following products: