Dell PowerVault 50F (Fibre Channel Switch) User Manual

Page 62

Advertising
background image

PowerVault™ 50F Commands: Dell™ PowerVault™ 50F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

file:///C|/Users/sharon_anand/Desktop/PowerVault/50f_enit/COMMANDS.HTM[3/15/2013 11:32:02 AM]

Port N regname error counter is nnnn sb 0

Probable cause:

Failure of G_Port and FL_Port ASIC

Action:

Replace the switch

Probable cause:

Failure of interface module

Action:

Replace the switch

Probable cause:

Failure of GBIC module connector

Action:

Replace GBIC module

DIAG-TIMEOUT, 1

Port N receive timeout.

Probable cause:

Failure of G_Port and FL_Port ASIC

Action:

Replace the switch

Probable cause:

Failure of interface module

Action:

Replace the switch

Probable cause:

Failure of GBIC module connector

Action:

Replace GBIC module

DIAG-DATA, 1, PortX:pass nn

Frame Tx4>->Rx4 payload byte offset nn is 0xXX sb 0xXX
(CMEM: SOF@ bufline/offset 0xXXXX/0xXX, error @ physical 0xXXXX/0xXX
Only one bad byte -- or -- Last bad byte at offset nn.

Probable cause:

Failure of motherboard

Action:

Replace the switch

Probable cause:

Failure of interface module

Action:

Replace the switch

Probable cause:

Failure of GBIC module connector

Action:

Replace GBIC module

DIAG-STATS, 1

(regname) counter wrong on port nn, is nn sb nn

Probable cause:

Failure of G_Port and FL_Port ASIC

Action:

Replace the switch

Probable cause:

Failure of Interface module

Action:

Replace the switch

DIAG-INIT, 1, portLB: pass nn

Port N failed to go active after initialization

Probable cause:

Failure of G_Port and FL_Port ASIC

Action:

Replace the switch

Probable cause:

Failure of interface module

Action:

Replace the switch

Probable cause:

Failure of GBIC module connector

Action:

Replace GBIC module

Advertising
This manual is related to the following products: