Dell PowerVault 50F (Fibre Channel Switch) User Manual

Page 29

Advertising
background image

Managing the PowerVault™ 50F Switch: Dell™ PowerVault™ 50F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

file:///C|/Users/sharon_anand/Desktop/PowerVault/50f_enit/MANAGE.HTM[3/15/2013 11:31:58 AM]

Name Server

The fibre channel protocol (FCP) inquiry data obtained by device probing may now be obtained from the
Name Server by retrieving the port symbolic name.

Common Transport (CT) requests and responses including Name Server are recorded in the portLog. A
typical trace is shown as follows, where port 4 logs in to the Name Server and issues command 217. It
receives an Accept (8002).

Jun 15 16:00:21.899 tReceive

Rx3

4 116

22fffffc,00210413,03000000

Jun 15 16:00:21.899 tSwitch

Tx3

4 116

23210413,00fffffc,02000000

Jun 15 16:00:21.933 tNSd

ctin

4 fc

00030217,00210413,00000100

Jun 15 16:00:21.933 tNSd

ctout 4 fc 00008002

Jun 15 16:00:21.933 tNSd

Tx3

4 0

03210413,00fffffc