Dell PowerVault 50F (Fibre Channel Switch) User Manual

Page 8

Advertising
background image

Installing the PowerVault™ 50F Switch: Dell™ PowerVault™ 50F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

file:///C|/Users/sharon_anand/Desktop/PowerVault/50f_enit/INSTALL.HTM[3/15/2013 11:31:55 AM]

Installing the Inner Slides

To install the inner slide onto the switch, perform the following steps:

1. Disassemble the inner and outer slides of the slide assembly by fully extending the inner slide, pressing

the release, and pulling the slide assembly apart.

2. Align the holes of an inner bearing slide with the holes on the side of the manifold and the switch (see

Figure 1-2).

The end of the manifold that has the gasket should be toward the center of the inner bearing slide.
Make sure the rivets on the manifold a face up. The end of the inner bearing slide that has the two slots
should be at the end of the manifold without the gasket.

Align the switch to the inner bearing slide and orient the front of the switch (with the input/output ports)
toward the end of the bearing slide with the large hole. The back of the switch will compress the gasket
on the manifold.

Figure 1-2. Attaching the Inner Bearing Slides and L-Brackets

3. Use four 10-32 x 1/4-inch screws to mount the inner bearing slide to the switch and manifold.
4. Repeat steps 2 and 3 to mount the second inner bearing slide to the other side of the switch and

manifold.

5. Using 10-32 x 1/4-inch screws, mount an L bracket, with the captive thumb screws, to each inner slide,

as shown in Figure 1-2.

Installing the Outer Slides

To install the outer slide in the rack, perform the following steps:

1. Use a 10-32 x 1/2-inch screw to mount a stationary bracket to an outer slide, as shown in Figure 1-3.

Figure 1-3. Attaching Stationary and Adjustable Brackets to an Outer Slide