Dell DX6000G User Manual

Page 22

Advertising
background image

22

About Your System

E1114 Ambient Temp

exceeds
allowed range.

Ambient temperature has

a reached a point outside

of the allowed range.

See "Troubleshooting

System Cooling

Problems" on page 147.

E1116 Memory

disabled, temp
above range.
Power cycle
AC.

Memory has exceeded

allowable temperature and

has been disabled to

prevent damage to the

components.

Remove AC power to the

system for 10 seconds and

restart the system.
See "Troubleshooting

System Cooling

Problems" on page 147.

If the problem persists,

see "Getting Help" on

page 169.

E1210 Motherboard

battery
failure. Check
battery.

CMOS battery is missing

or the voltage is outside of

the allowable range.

See "Troubleshooting the

System Battery" on

page 146.

E1211 RAID

Controller
battery
failure. Check
battery.

RAID battery is either

missing, bad, or unable to

recharge due to thermal

issues.

Reseat the RAID battery

connector. See

"Troubleshooting System

Cooling Problems" on

page 147.

E1216 3.3V Regulator

failure.
Reseat PCIe
cards.

3.3 V voltage regulator has

failed.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting

Expansion Cards" on

page 155.

E1229 CPU # VCORE

Regulator
failure.
Reseat CPU.

Specified processor

VCORE voltage regulator

has failed.

Reseat the processor(s).

See "Troubleshooting the

Processors" on page 156.
If the problem persists,

see "Getting Help" on

page 169.

Table 1-1. LCD Status Messages

(continued)

Code

Text

Causes

Corrective Actions

book.book Page 22 Wednesday, December 22, 2010 2:13 PM