Dell DX6000G User Manual
Page 36
 
36
About Your System
Alert! iDRAC6 not 
responding. 
Rebooting.
The optional iDRAC6 is not
responding to BIOS
communication either
because it is not functioning
properly or has not
completed initialization.
The system will reboot.
Wait for the system to
reboot.
Alert! iDRAC6 not 
responding. 
Power required 
may exceed PSU 
wattage.
Alert! 
Continuing 
system boot 
accepts the risk 
that system may 
power down 
without warning.
The optional iDRAC6
has hung.
The optional iDRAC6 was 
remotely reset while system
was booting.
After AC recovery, the 
optional iDRAC6 takes
longer than normal to boot.
Remove AC power to the
system for 10 seconds and
restart the system.
Alert! Node 
Interleaving 
disabled! Memory 
configuration 
does not support 
Node 
Interleaving. 
The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a memory
module has failed) so that
node interleaving cannot be
supported. The system will
still run, but without node
interleaving.
Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. Check
other system messages for
additional information for
possible causes. For memory
configuration information,
If the problem persists,
Table 1-2. System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 36 Wednesday, December 22, 2010 2:13 PM