Dell DX6000G User Manual
Page 37
 
About Your System
37
Alert! Power 
required exceeds 
PSU wattage. 
Check PSU and 
system 
configuration. 
Alert! 
Continuing 
system boot 
accepts the risk 
that system may 
power down 
without warning.
The system configuration
of processor(s),
memory modules,
and expansion cards may
not be supported by the
power supplies.
If any system components
were just upgraded,
return the system to the
previous configuration.
If the system boots without
this warning, then the
replaced component(s) are
not supported with this
power supply. If Energy
Smart power supplies are
installed, replace them with
High Output power supplies
to use the components.
Alert! Redundant 
memory disabled! 
Memory 
configuration 
does not support 
redundant 
memory.
Memory Sparing or Memory
Mirroring was enabled in the
system setup program, but
the current configuration
does not support redundant
memory. A memory module
may be faulty.
Check the memory modules
for failure. See
Reset the memory setting,
if appropriate. See "Using
Alert! System 
fatal error 
during previous 
boot.
An error caused the system to
reboot.
Check other system
messages for additional
information for possible
causes.
Table 1-2. System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 37 Wednesday, December 22, 2010 2:13 PM