Dell DX6000G User Manual

Page 33

Advertising
background image

About Your System

33

I1911 LCD Log Full.

Check SEL to
review all
Errors.

LCD overflow message.

A maximum of ten error

messages can display

sequentially on the LCD.

The eleventh message

instructs the user to check

the SEL for details on the

events.

Check the SEL for details

on the events.
Remove AC power to the

system for 10 seconds or

clear the SEL.

I1912 SEL full.

Review & clear
log.

The SEL is full of events

and is unable to log any

more.

Check the SEL for details

on the events, then clear

the SEL.

I1920 iDRAC6 Upgrade

Successful

Optional iDRAC6 has

been upgraded

successfully.

Information only.

W1228 RAID

Controller
battery
capacity <
24hr.

Warns predictively that

the RAID battery has

less than 24 hours of

charge left.

Allow RAID battery to

charge to greater than

24 hours of

sustained charge.
If problem persists,

replace RAID battery.

W1627 Power required

> PSU wattage.
Check PSU and
config.

The system configuration

requires more power

than what the power

supply can provide.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.

W1628 Performance

degraded.
Check PSU and
system
configuration.

The system configuration

requires more power

than what the power

supply can provide, but it

can boot if throttled.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

Glossary

at support.dell.com/manuals.

Table 1-1. LCD Status Messages

(continued)

Code

Text

Causes

Corrective Actions

book.book Page 33 Wednesday, December 22, 2010 2:13 PM