Dell DX6000G User Manual

Page 24

Advertising
background image

24

About Your System

E1410 Internal Error

detected.
Check "FRU X".

Specified processor has an

internal error. The error

may or may not have been

caused by the processor.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 169.

E1414 CPU # temp

exceeding
range. Check
CPU heatsink.

Specified processor is out

of acceptable temperature

range.

Ensure that the processor

heat sinks are properly

installed. See

"Troubleshooting the

Processors" on page 156

and "Troubleshooting

System Cooling

Problems" on page 147.

E1418 CPU # not

detected.
Check CPU is
seated
properly.

Specified processor is

missing or bad, and the

system is in an

unsupported

configuration.

Ensure that the specified

microprocessor is

properly installed. See

"Troubleshooting the

Processors" on page 156.

E141C Unsupported

CPU
configuration.
Check CPU or
BIOS revision.

Processors are in an

unsupported

configuration.

Ensure that your

processors match and

conform to the type

described in the processor

technical specifications

outlined in your system’s

Getting Started Guide.

E141F CPU # protocol

error. Power
cycle AC.

The system BIOS

has reported a processor

protocol error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 169.

Table 1-1. LCD Status Messages

(continued)

Code

Text

Causes

Corrective Actions

book.book Page 24 Wednesday, December 22, 2010 2:13 PM

Advertising