8.2.2.5 Alarm Setting

In the Alarm Setting dialog box, click Add to insert and set new alarm setting, click Delete to remove the

selected alarm setting, click Update to save the setting, Exit to exit without saving, and Default to revert back

to original factory setting.

(1)

(2)

(3)
(4)

(5)

(6)

(7)

(8)

1. Click Add to insert and set a new alarm setting. Click the items in the (8) Alarm Setting List if you want to

modify the alarm setting.

2. In (1) No./Name/Description enter alarm name and description. Alarm No. will be created by DVR

system.

3. In (2) Enable Time, the number from 00 to 23 represent the time in 24-hour clock. Select the time and click

the block you want to activate or deactivate the alarm function. When it is deactivated the color of the block

turns white.

4. In (3) Conditions

, you can set “Trigger if any” to activate if it falls to one of the conditions or “Trigger if all

to activate if it falls to all conditions.

5. In (4) Camera section, select and click on the camera number (01 to 16) in Motion Detected and Video

Loss to set the condition for the system to alarm.

-

Motion Detected: select and click on the camera number (01 to 16) to set the condition for the system

to alarm. Right-click on the camera number to setup the system to send out the alarm when motion has

been detected last the time that user has entered in Continuous trigger duration.

-

In Video Loss, click the camera number (01 to 16) to set the alarm condition when video is lost.

Right-click on the camera number (01 to 16) to setup the system to send out the alarm when video has

been lost to last the time that user has entered in Continuous trigger duration.