Alarm setting, 9 alarm setting – AVer EXR5016_series user manual User Manual

Page 83

Advertising
background image

75

3.9

Alarm Setting

In the Alarm Setting dialog box, click Add to insert and set new alarm setting, click Delete to remove the

selected alarm setting, click OK to exit and save the setting, Cancel to exit without saving. Click Default will

back to factory default value.

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

1. Click Add to insert and set a new alarm setting. Click the items in the (8) Alarm Setting List if you want to

modify the alarm setting.

2. In (1) No./Name/Description enter alarm name and description. Alarm No. will be created by DVR

system.

3. In (2) Enable Time, the number from 00 to 23 represent the time in 24-hour clock. Select the time and click

the block you want to activate or deactivate the alarm function. When it is deactivated the color of the block

turns white.

4. In (3) Conditions

, you can set “Trigger if any” to activate if it falls to one of the conditions or “Trigger if all

to activate if it falls to all conditions.

5. In (4) Camera section, select and click on the camera number (01 to 16) in Motion Detected and Video

Loss to set the condition for the system to alarm.

6. In (5) Sensor, select and click on the sensor number to set the condition for the system to alarm. If the

sensor normal status is high, set the sensor condition to low.

-

IP Camera Sensor: To adjust sensor high/low that is connected on the IP camera.

Advertising
This manual is related to the following products: