Salter Brecknell 650 User Manual

Page 19

Advertising
background image

19

4.3.1

DISPLAYING THE MEMORY ACCUMULATOR

1. Press the MR soft key. The scale briefly displays the total number of pieces.

4.3.2

ADDING TO THE MEMORY ACCUMULATOR

1. Press the M+ soft key. The scale adds the current number of pieces to the memory

accumulator, and then briefly displays the total number of pieces.

4.3.3

SUBTRACTING FROM THE MEMORY ACCUMULATOR

1. Place the pieces you wish to subtract on the scale.
2. Press the FUNCTIONS key.
3. Press the M - soft key. The scale subtracts the current number of pieces from the

memory accumulator, and then briefly displays the total number of pieces.

4. When finished, press the CLR key to return to the main screen.

4.3.4

CLEARING THE MEMORY ACCUMULATOR

1. Press the MC soft key. The scale asks if you wish to clear the memory accumulator.
2. Press the Yes soft key to clear the accumulator memory or press the No soft key if you

do not wish to clear the accumulator memory.

NOTE:

To exit the memory accumulator function, press the CLR key once.

4.4

USING THE TARGET VALUE

This function works in conjunction with the piece counting or weighing mode feature and

allows your scale to act as a checkweigher. This is useful if you are filling a container with a

pre-determined amount of items or material.

To use, you must enter two values – a lower limit value and an upper limit value. These are

chosen based on the tolerance of your target value. For example, if you wish to fill a bottle

with 100 items and you have a tolerance of

±

2 pieces, you would set your lower limit value

to 98 and your upper limit value to 102. The lower and upper limit values may be the same if

you have no tolerance allowance.

If the number of items on the platform is within the two limits, the scale flashes the “Target”

soft and beeps.

To enable the weight or pcs mode:

1. Press the * key
2. Press the CONFIG soft key and the scale prompts for password. Enter 1111.
3. Press the MORE soft key
4. Press the SETPNT soft key.
5. Press the SP1 soft key.
6. Press either the weight or pcs soft key to enable the function.
7. Enter the upper and lower values. Press the ENT key to enter.
8. Press clear to step back one level.
9. Press the SP2 key and enter the jog time. Press ENT to enter.
10. Press clear to step back one level.

Advertising