Salter Brecknell 650 User Manual

Page 40

Advertising
background image

40

B.2.3 CONNECTION TO A 610 OR 630

A 610 or 630 may be used for high precision calculations of average piece weights. The

610 or 630 can transmit the APW to the TC2010.

650 CONFIGURATION

1. Use COM 2 and set to scanner – see B.2.1

2. Use an NMC-2 male to male cable.

610 OR 630 CONFIGURATION

1. Set A 6 to APW transmit mode

2. Connect MNC-2 cable to COM 1

TO USE THE APW FROM THE 610

1.

From the 650

2. Make sure the 610 is counting the pieces you want the average piece weight

from.

3. Press the SAMPLE soft key on the 650.

4. Press the APW soft key on the 650.

5. Press the TCS soft key on the 650.

6. The APW from the 610 is retrieved and the 650 begins counting

1. From the 610 OR 630

2. Use the 610 or 630 to count pieces you want the average piece weight from.

3. Press the PRINT key on the 610 to transmit the APW to the 650.

CAUTION

: this will over-write any existing APW currently being used in the

650.

Advertising