37

B.1.2 DEFAULT PRINT FORMAT

Figure B-4 shows the fixed format of the print format. The fields can be enabled or

disabled as described in Section 5.5.4.

FIGURE B-4: Default Print Format for Thermal Printer

B.1.3 CONNECTING TO MP-20

When connecting the MP20 to the 630, use an NMC-1 cable from COM 1. Connect the

other end of the NMC-1 cable to the printer cable supplied with the MP-20. Configure

section 5.5.3 to select the MP-20. Create a label using section 5.5.4. Select the fields to

print in human readable only. If a field has a bar code selected, it may not fit the entire bar

code across the two inch width of the label causing an incomplete, unreadable bar code.

B.2 COM2 SERIAL PORT

B.2.1

CONNECTING THE SCANNER, REMOTE DISPLAY, TC100 OR COMPUTER

The COM2 serial port is a full duplex RS-232 port designed for connection to a computer,

scanner or remote display. Figure B-5 shows the serial port pinout. Figure B-6

shows a suggested cable diagram for a PC-type computer. Figure B-7 shows a

suggested cable diagram for a scanner. The cable shown in Figure B-6 is a

standard Salter Brecknell cable – Model NMC-1.

Note

: Earlier 650 models may not be equipped with a COM2 serial port.

1. Plug the scanner, remote display or computer communication cable (not

included) directly into the DSUB9 serial port connector.

Pin No.

Pin Name

2

Receive Data

3

Transmit Data

Signal Level

RS-232
RS-232

5

Signal Ground

RS-232

2

3

5

Front View