10 frame fab – Oldcastle BuildingEnvelope Reliance-TC User Manual

Page 10

Advertising
background image

FRAME FABRICATION

R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

TM

1.3 Fabricate vertical mullions for horizontal members using the DJ-100 drill jig. Drill holes for shear block using

holes marked "A" and "B". SEE FIGURE 3. When working off horizontal centerlines, use the scored lines to align the

jig with the centerline.

FIGURE 3

Vertical Fabrication

Top of

horiozontal

FS-9 (typ)

WW-181-01

WW-104-01 anchor optional
for head or sill Maximum load

375 lbs per anchor.
(750 lbs. end reaction)

1 1/4"

#11 (.191Ø) holes for
#14 fasteners

2 1/4"

3/4"

A

A

B

C

D

C

C

D

C

2 1/4"

3/4"

1 1/4"

Top of

horizontal

1 1/4"

typ.

AW-181-01

WW-102-01 Tee
anchor @ mullion
WW-103-01 F
anchor @ jamb

Seal mull cap

Apply sealant

to mullion prior

to installing

mull cap

Type I
Vertical Layout

Type II
Vertical Layout

AW-181-01

(Optional)

MAY 2013

10

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com