GLAZING
R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L
TM
2 1/2"
SSG vertical
Quarter points
Quarter points
1/4" splice joint
1/2"
face cover
splice joint
1
1
8
"
Face cover
(dashed)
FS-325
Pressure
Plate Splice
Face Cover
Splice
FIGURE 30
Pressure Plate / Face Cover Splicing & Sealing at SSG Mullions
(Intermediate Horizontal Shown; Head & Sill Similar)
3.21 After removing horizontal temporary retainers, locate pressure plates and face covers to run
continuous over SSG mullions. Pressure plate and face covers are not to exceed 3 lites in length.
Splice pressure plate and face covers at SSG mullion center line per
FIGURE 30.
SEALING NOTES:
1. Prior to attaching face covers, seal between
pressure plates.
2. Attach face covers and seal joint (a foam
backer rod can be used to aid in sealing)
Butt-spice isolator
as required (seal joint)
1/2"
face cover
splice joint
Backer rod between
face cover and
pressure plate
Pressure bar
(dashed)
Face cover
Weep holes
Attachment holes
MAY 2013
31
Phone: 1-866-OLDCASTLE (653-2278)