41 reglaze, Reglazing procedures – Oldcastle BuildingEnvelope Reliance-TC User Manual

Page 41

Advertising
background image

REGLAZING PROCEDURES

D.1 REGLAZING MUST BE DONE FROM EXTERIOR. Carefully remove face covers surrounding the lite of glass to be

deglazed. If WW-520 / WW-420 mullions are used remove horizontal face covers only. SEE FIGURE 43.

D.2 Remove pressure plates at the lite to be replaced. Remove the exterior wedge gaskets at the vertical mullions for captured

vertical applications.

D.3 Remove lite of glass and existing interior gaskets from the opening. Clean debris and sealant from the framing members

and pressure plates.

D.4 Install new gaskets into framing. Set new lite of glass, centering in opening. Refer to the GLAZING section of this manual

for proper procedure.

D.5 Reinstall pressure plates and seals per GLAZING section of this manual.

Non-metallic shim

FIGURE 43

Reglazing

Pry bar

CORNER GLAZING

R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

TM

MAY 2013

41

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

Advertising