GLAZING

R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

TM

FIGURE 27

Side Block Installation

Expanded

GP-115 "W" Block

(See view at left)

"W" Block

Temporary

wedge gasket

GP-114 Side block at

shallow pocket

(install before glass is set)

Type I Vertical

Type I Vertical

Type II Vertical

MAY 2013

29

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

3.16 If required, install GP-114 and GP-115 side blocks on Type I vertical mullions and GP-111 for

Type II vertical mullions at centerline of each lite along vertical edges. Hold GP-111 and GP-114 in

place with a dollop of silicone. For framing that may be subjected to seismic events, consult glass

manufacturer for preferred location. See FIGURE 27. NOTE: Side blocks are not required at SSG

mullions.

3.17 Repeat steps 3.3. through 3.16 until all glass is set, working row by row up the elevation.