19 frame install, Figure 15 type i zone plug installation, Frame installation – Oldcastle BuildingEnvelope Reliance-TC User Manual

Page 19

Advertising
background image

R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

TM

FIGURE 15

Type I Zone Plug Installation

STEP 1

Seal front and back gasket races, and adaptor
race. Tool sealant into races to insure proper
seal. Sealant should be applied from just above
horizontal leg down 1/2" into area for zone plug.

Tool sealant into joint between

mullion and horizontal from
exterior and interior of

glazing pocket

2.5 Apply sealant to all contact surfaces on vertical and horizontal mullions where zone plugs will be installed. Install

at the end of each horizontal mullion by sliding plug down into pocket from above. Tool sealant around all sides of the
zone plug in the glazing pocket to ensure a watertight seal.

SEE FIGURE 15 below & page 20 for System 1, SEE

FIGURE 16, page 21 for System 2 installation .

FRAME INSTALLATION

MAY 2013

19

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

Advertising