GENERAL INFORMATION

PRODUCT USE

The Reliance -TC curtain wall system is intended for installation by glazing professionals with

appropriate experience. Subcontractors without experience should employ a qualified person to provide field

instruction and project management.

Oldcastle BuildingEnvelope does not control the application or selection of its product configurations, sealant

or glazing material and assumes no responsibility thereof. It is the responsibility of the owner, architect and

installer to make these selections in strict compliance with applicable laws and building codes.

Consult sealant manufacturer for review and recommendation of sealant application. Follow sealant

manufacturer’s recommendations and literature for proper installation.

The air and water performance of the Reliance -TC curtain wall system is directly related to the

completeness and integrity of the installation process both the seal installed at the shear blocks and the glazing

gasket installed at the interior side of the glass. All pressure plates must also be installed properly. To insure top

performance for this system, particular attention should be given the following procedures:

1. Surfaces to be sealed should be cleaned with isopropyl alcohol or solvent and dried as recommended by

sealant manufacturer to remove all dirt and cutting oils. Sealant at shear blocks should be a minimum 3/16˜

diameter nominal placed completely around the top, face and bottom of the shear block without gaps in the

sealant. Exposed surfaces should be cleaned after installing the horizontal. Inspect joint for complete

sealant contact, especially where the horizontal meets the face of the vertical member. Repair joint as

required.

2. The interior glazing gasket should be installed so as to avoid stretching, buckles or tears. Corners must be

cut square, sealed and butted together. To avoid damage to gasket and corner joints during glazing, glass

should be level and straight during installation.

3. Vertical movement of mullion at intermediate floors requires special expansion joints and glazing materials.

See page 13 for details which permit 1/4” movement. For designs and applications that may require greater

movement or special considerations please contact your local Oldcastle BuildingEnvelope facility.

Variations on the details shown are inevitable and are not the responsibility of Oldcastle BuildingEnvelope

when drawn by others. Oldcastle BuildingEnvelope strongly encourages its customers to use its Engineering

department for calculations and shop drawings.

For Structural Silicone Glazing (SSG) applications, the stress on the silicone should not exceed 20 PSI. Consult

sealant manufacturer for specific applications to ensure proper loading on silicone joint. Alternate spacer gaskets

are available to accommodate larger sealant contact widths. Consult your nearest Oldcastle BuildingEnvelope

facility for assistance.

Consult glass manufacturer for correct setting block location and length for glass sizes in excess of 40 sq.ft.

MAY 2013

3

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

PROTECTION AND STORAGE
Handle all material carefully. Do not drop from the truck. Stack with adequate separation so the material will not

rub together. Store material off the ground, protecting against the elements and other construction hazards by

using a well ventilated covering. Remove material from package if wet or located in a damp area. For further

guidelines consult AAMA publication ˆCare and Handling of Architectural Aluminum From Shop to Site.˜

R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L