R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

TM

GLAZING

FIGURE 26

Sealing Pressure Plates

Seal ends of pressure
plate to vertical face

1/32"

3.14 Seal ends of horizontal pressure plates to the verticals. Tool sealant into the joint. SEE FIGURE 26.

3.15 Install horizontal face covers, leaving an equal gap at each end. Make sure the weep hole is on the bottom.

Install covers using a wood block to protect the cover and a dead blow soft face hammer.

For elevations requiring vertical mullion splices, refer to the VERTICAL SPLICING section, page 34 , before

continuing the installation.

5/16"Ø Weep holes

Locate at 1/4 points

GP-113 Wedge
See notes below for installation

GP-103 Gaskets
See notes below for installation

GP-103 Gaskets
See notes below

for installation

WW-162

Cut length =
D.L.O. - 1/4"

WW-110 Face cover

Weep face cover at mid-lite.

(See FIGURE 4, PAGE 9)

GLAZING NOTES:

1) INTERIOR GASKETS: GP-103 dense EPDM gasket

EXTERIOR GASKETS: GP-103 at pressure plates,
GP-113 wedge gasket at WW-520 verticals.

2) Remove gasket from reels and allow to relax overnight
3) Cut gaskets 1/4" longer per foot to allow for relaxation.

MAY 2013