35 trans glazing – Oldcastle BuildingEnvelope Reliance-TC User Manual

Page 35

Advertising
background image

TRANSITION GLAZING

R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

TM

FIGURE 34

Installing Glazing Adaptors

WW-145

Vertical

Horizontal

WW-130

1

2

1

2

Seal adaptors at joint

(Marry at groove)

Seal Groove

(Marry at corners)

FIGURE 35

Sealing Glazing Adaptors

Adaptor installation at AW vertical

mullions and horizontals.

MAY 2013

35

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

A.1 Install vertical adaptors first, leaving an equal overlap into each pocket. SEE FIGURE 34. Refer to

VERTICAL SPLICING, page 37 if vertical mullion is spliced within a spandrel lite. Transition adaptors must be

installed after mullion splice is sealed.

A.2 Install horizontal adaptors maintaining an equal gap at each end. Once all adaptors have been installed in the

opening, seal all corner joints. Run a bead of sealant in the groove formed between the adaptor and mullions. This
seal must be continuous around the opening and must marry with the seal at the corner joints. SEE FIGURE 35.

Note: Alternate glass thickness not available for the high performance Reliance-TC system. This product is designed

for 1" glazing with optional triple glaze available.