Crestron electronic Multimedia Presentation System 300 MPS-300 User Manual

Page 17

Advertising
background image

Crestron MPS-300

Multimedia Presentation System 300

Connectors, Controls & Indicators

#

CONNECTORS

1

,

CONTROLS &

INDICATORS

DESCRIPTION

1

NET LED

(1) yellow LED, indicates Cresnet bus activity.

2

MSG LED

(1) yellow LED, illuminates when a message is
present in the message log. To view the
contents of the message log, use the front
panel buttons or Crestron Toolbox™.

3 & 4

RESET BUTTONS

HW-R – Initiates system hardware reset.
SW-R – Pressing this in combination with
HW-R button performs a system restart without
loading the program. Pressing it alone
momentarily while the system is running
restarts the program.

5

COMPUTER

Pin 1 Pin 2

Pin 4 Pin 3

(1) USB Type B female; USB 1.1 computer
console port (cable included)

PIN

DESCRIPTION

1

+5 VDC

2

Data -

3

Data +

4

Ground

6

PROGRAM OUT (L/R)

(1) 5-pin 3.5 mm detachable terminal block;
Balanced/unbalanced stereo line-level output;

Output Impedance: 200 ohms balanced,
100 ohms unbalanced;

Maximum Output Level: 4 V

rms

balanced,

2 V

rms

unbalanced

7

AUDIO INPUTS 1-5

(5) 5-pin 3.5 mm detachable terminal blocks;
Balanced/unbalanced stereo line-level inputs;

Input Impedance: 24k ohms
balanced/unbalanced;

Balanced Input Level: -20 to +12 dBV;
4 V

rms

maximum;

Unbalanced Input Level: -20 to +6 dBV;
2 V

rms

maximum

(Continued on following page)