Hardware connections for the mps-300, rear – Crestron electronic Multimedia Presentation System 300 MPS-300 User Manual

Page 30

Advertising
background image

Multimedia Presentation System 300

Crestron MPS-300

Hardware Connections for the MPS-300, Rear

TO SPEAKERS:

8-OHM STEREO (MPS-300)

70 VOLT MONO (MPS-300-70V)

100 VOLT MONO (MPS-300-100V)

AUDIO INPUTS:

FROM VIDEO AND

RGB SOURCES

MICROPHONE/LINE INPUT:

FROM MICROPHONE OR

LINE-LEVEL SOURCES

PROGRAM AUDIO OUTPUT:

TO AMPLIFIER OR

AMPLIFIED SPEAKERS

IR/SERIAL OUT:

TO IRP2 IR EMITTER PROBE

or ONE-WAY SERIAL

CONTROLLED DEVICES

IR IN:

FROM

CNXRMIRD IR

RECEIVER

INPUT:

FROM DEVICE OUTPUTS

CONTACT OR RELAY

CLOSURES (24 VOLTS MAX)

RELAY OUTPUT:

TO CONTROLLABLE

DEVICES

COM A & COM B:

BI-DIRECTIONAL RS-232 WITH

HARDWARE & SOFTWARE

HANDSHAKING AND MODEM CONTROL

LAN:

10/100 BASE-T

ETHERNET TO LAN

CRESNET:

TO ANY

CRESNET

DEVICE

POWER:

FROM LINE VOLTAGE

GROUND:

TIE ALL SOURCE AND

DEVICE GROUNDS TO

GROUND TERMINAL

OUTPUTS 1-4:

TO COMPOSITE,

COMPONENT, S-VIDEO,

AND RGB INPUTS OF

DISPLAY DEVICE

RECORD OUTPUT:

TO CODEC, RECORDING

DEVICE, OR ASSISTIVE

LISTENING SYSTEM

SPEECH OUTPUT:
TO AMPLIFIER OR

AMPLIFIED SPEAKERS

INPUTS 1 & 2:

FROM COMPOSITE,

COMPONENT, OR

S-VIDEO SOURCES

INPUTS 3-5:

FROM RGBHV &

RGBS SOURCES

OUTPUTS 6 & 7:

QM OUTPUTS TO

QM DEVICES

INPUTS 6-8:

FROM QM
SOURCES

OUTPUT 5:

TOUCHPANEL OUTPUTS

TO “QM” or “CH” TYPE

TOUCHPANELS

When running the out-of-the-box program, the MPS-300 can support the following
Crestron devices:

• (2) APAD
• (2) C2N-FTB
• (2) CNX-B12
• (2) C2N-DB12
• (2) CLW-DIM1RF / CLW-DIMS1RF (requires Crestron Toolbox for

implementation)

• (2) CLW-SW1RF / CLW-SWS1RF (requires Crestron Toolbox for

implementation)

• (1) QM-AMP3x80MM/SR
• (1) C2N-MNETGW
• (1) CLS-C6
• (1) RoomView Express or RoomView Server Edition connection

CAUTION: Speakers must be rated to full available output.

CAUTION: Do not bridge speaker outputs

CAUTION: All source devices should be grounded to the MPS-300.

NOTE: The MPS-300 can only be powered by the included power cord. Power
cannot be supplied from network devices that are connected to the mini-terminal
block connectors.

NOTE: For Cresnet, CAT5, and QuickMedia connections, use Crestron Certified
Wire.

NOTE: When running the out-of-the-box program, relays 1 and 2 are momentary.