1.

Mount the Remote Sensor on a solid surface away from

doors, corners, air outlets, drafts or heat generating equipment.
Do not mount the Remote Sensor directly on an outside wall or
wall adjacent to a boiler room. Use a piece of foam insulation
behind the sensor to insulate it from a hot or cold surface. The
recommended height is 1.2 to 1.5 meters above the finished
floor.

2.

遥控传感器应安装在坚实的墙壁上,尽量远离门口

、角落、送风口、或其它串风的地方,尽量远离生热设备
。不要直接挂载在外 墙或毗邻锅炉的房间。使用一块泡沫
保温材料隔离遥控传感器背 面 的冷或 热表面。建议安装
的高度为离地 1.2 至 1.5 米

3.

Remove the sensor cover plate by removing the two

Allen head screws at the top of the cover using the Allen head
wrench provided in the kit.(Fig.2) Mark the mounting points at
the desired location within the wine cellar. Also mark the
location of the communication cable connection as this area
will require sufficient clearance, for instance 3.8cm hole in the
wall for flush mounting of the sensor plate.

从盖子顶部使用提

供的六角扳手松 开

遥控传感器的

盖子(图 2),

标好通讯电

缆连接的位置,如果控制器背板需要紧贴墙壁,应个位置
需要足够的间隙,大概要在墙上打一个 3.8 厘米洞

4.

Drill two (2) .32cm holes and insert anchors (provided)

within the mounting surface. Anchors may not be required if
securing to a wall stud or racking system. (Fig.3) 钻两个(

2)

0.32 厘米的洞,并在安装表面插入钉锚(提供件)。如果
控 制器背板安装在木制的墙或框货架系统,可能不需要钉
锚。(图 3)

5.

Plug in the communication cable to the back of the

Remote Sensor and attach to the wall using the two screws
provided in the kit. (Fig.4) 通信电缆插入遥控传感器板背
面的插头,用提供的两个螺丝将 传感器板背面垫板装到墙
上。 (图 4)

6.

Plug the Remote Sensor cables into the splitter device at

the WG unit along with the communication cable for the
Remote Interface Controller. (Fig.5)将遥控传感器通信电缆
和遥控控制器电缆同时插入主机上的分离器插口 (图 5)

Fig. 2

Fig. 3

Fig.4

Fig. 5

Fig 4

Fig. 3

Fig. 5