Unit is Operating and Blows Evaporator Air, but the Supply Air is Not
Colder Than the Return Air from the Cellar

主机工作, 吹出蒸发器空气,但气源温度低于地窖里的回风空气

Possible Cause 可能的问题 Solution 解决方法

Thermostat not set up properly Check thermostat setup in the manufacture’s
温控器设置不正确 thermostat guide

检查温控器设置指南

Compressor not operating 压缩机不工作 High pressure switch open (button up)

高压开关打开

Condenser airflow is blocked Remove blockage 取除堵塞
冷凝器气流受阻 Clean filter and coil (if needed)

清洁过滤网和线圈(如需要)


Head Pressure (HP) switch is open Reset HP switch See reset instructions on
page 42
头压力开关打开 复位高压卡关。见 42 页。

Problems Controlling Cellar Temperature 酒窖温度控制问题

Problems are occurring even though the unit seems to be fully operational – evaporator fan blows
air into the cellar and compressor and condenser fan runs.

主机全面运行, 仍然有问题 - 蒸发器风扇向酒窖吹风,压缩机和冷凝器风扇运行

Cellar Temperature too cold (below 11°C) when unit is running
当设备运行时,酒窖温度太冷(低于 11 ° C


Possible Cause 可能的问题

Solution 解决方法

Thermostat set too low on cooling

Reset thermostat to higher cooling

温控器冷却设置太低,

temperature

复位并提高温控器冷却温度

Heating coil (optional) not operating

Check for temperature rise across coil

加热线圈(可选)不工作

检查线圈温度上升

Thermostat set too low on heating

Reset thermostat to higher heating

temperature