Changing Jumper Positions (Averaging reading from Remote
Sensor)
改变条线位置 (采用传感器平均值)

If using multiple Remote Temperature/Humidity sensors in
your application, refer to the photos showing the need to
change the jumper locations internal to the control board on
each remote sensor (up to 3 maximum).
如果在应用程序中使用多个遥控温度/湿度传感器,请参
阅照片的显示, 改变每个传感器内部的跳线位置(最高可
达 3)见控制电路板。



For the control to average all of the sensors utilized (if more
than one), the jumper must be in different positions on the
pins. 如果使用多个传感器, (控制采用平均值),跳线位
置必须选好不同的位置。




As you can see, there are three pin settings. To access the
jumper:
如图所示 ,有 3 个针脚的设置。

1. Remove the two-set screws holding on the plastic cover. This
procedure allows the control to go to each remote sensor in
sequence to average. Failure to perform this procedure will
result in the system reading only one sensor and not the average
of multiple sensors.

打开塑料盖上的 2 个螺丝,
这个手续允许控制程序进行
序列式采集每个远程传感器的平均值。

不执行此过程将导致只有一个传感器的读数,
而不是整个系统多个传感器的平均值。

NOTE: If multiple sensors control the WG unit, change factory default in configuration
setting 10 to “averaging.” You will need access code from Air Innovations service to use
in configuration 8 to reach configuration 10.

注意:如果使用多个传感器,在设置 10 请确认你的配置更改为使用
“平均值”。进入设置 10 前,你必须已在设置 8,使用公司提供的密码,
进入设置 10

Jumper Position1

Jumper Position 2

Jumper Position 3