Nextteq Irritant Smoke Tube Kit Manual

The Gastec Irritant Smoke Tube (Part Number 9501) is manufactured by the Gastec Corporation.

Nextteq is Gastec’s exclusive U.S. master wholesale distributor.

Page 15

Tel: 813-249-5888 Toll free: 877-312-2333 Fax: 813-249-0188 Toll free: 877-312-2444 www.nextteq.

P/N 9505 Rev F 8/09

Warnings

to an increased concentration of smoke or fumes, resulting in

property damage, serious injury, or death.

45. Do not dispose of irritant smoke tubes with turpentine,

alcohols, or amines. Exposure to turpentine, alcohols, or

amines may result in chemical reaction and fire resulting in

property damage, serious injury, or death.

46. Before using or attempting to use this product, users should

wear the following:
A. Safety gloves in accordance with OSHA standards and

good practice.

B. Respiratory protection in accordance with OSHA 29 CFR

1910.134 and NIOSH 42 CFR 84.

C. Eye protection in accordance with OSHA standards

and good practice. Contact lenses should be worn in

strict compliance with applicable NIOSH, OSHA, and

ACOEM standards.

47. This product(s) is designed for qualitative respiratory fit testing

in ambient atmospheres of 40% relative humidity to 90%

relative humidity. Do not use this product(s) in atmospheres

of less than 40% relative humidity. Use of this product(s)

below 40% relative humidity may increase the irritant effect

of the smoke.

48. Do not fit test N95, R95, P95, N99, R99, or P99 particulate

respirators with a Gastec Irritant Smoke Tube. Fit testing the

particulate respirators listed above with a Gastec Irritant

Smoke Tube may result in serious personal injury, sickness,

and/or death.