Nextteq Irritant Smoke Tube Kit for Respirator Fit Testing and Airflow Indication User Manual

Page 36

Advertising
background image

Nextteq Irritant Smoke Tube Kit Manual

The Gastec Irritant Smoke Tube (Part Number 9501) is manufactured by the Gastec Corporation.

Nextteq is Gastec’s exclusive U.S. master wholesale distributor.

Page 33

Tel: 813-249-5888 Toll free: 877-312-2333 Fax: 813-249-0188 Toll free: 877-312-2444 www.nextteq.

P/N 9505 Rev F 8/09

Operating Instructions

VII. operatIng InStruCtIonS for aIrfloW IndICatIon
a. required Steps before Smoke generation
1. Before using this product, read, understand, and comply

with all labels, warnings, instructions, and other literature

accompanying the product including but not limited to this

manual, the MSDS (also available as P/N 90040) in this

manual, and Gastec Instructions and Warnings (included in the

box of Gastec Irritant Smoke Tubes No. 9501).

2. Inspect this product and associated equipment for damage or

defects before using.

b. Steps for Smoke generation
1. Determine where the airflow indication is needed.
2. Break the tip off a fresh tube by bending each tube end in the

tube tip breaker supplied with the Nextteq Irritant Smoke Tube

Kit (P/N 9500).

3. Place the black cap on one broken end of the smoke tube.
4. Pointing the tube end with the black cap away from you, insert

the other end of the tube into the aspiration bulb pump, being

careful not to compress the bulb.

5. Immediately before commencing use, remove the black cap

from the end of the smoke tube.

note:

Retain the black cap for later use.

6. Holding the pump at half arm’s length away from you, aim the

smoke tube tip away from you and other people in the area.

Advertising