The Gastec Irritant Smoke Tube (Part Number 9501) is manufactured by the Gastec Corporation.

Nextteq is Gastec’s exclusive U.S. master wholesale distributor.

Page 31

Tel: 813-249-5888 Toll free: 877-312-2333 Fax: 813-249-0188 Toll free: 877-312-2444 www.nextteq.

P/N 9505 Rev F 8/09

Operating Instructions

F. Ensure that the test subject does not have any hair growth,

beard, mustache, or sideburns which cross the respirator

sealing surface or any type of apparel or equipment that

interferes with a satisfactory respirator fit.

b. Steps for Smoke generation
1. Break the tip off a fresh tube by bending each tube end in the

tube tip breaker supplied with the Nextteq Irritant Smoke Tube

Kit (P/N 9500).

2. Place the black cap on one broken end of the smoke tube.
3. Pointing the tube end with the black cap away from you, insert

the other end of the tube into the aspiration bulb pump, being

careful not to compress the bulb.

4. Immediately before commencing use, remove the black cap

from the end of the smoke tube.

note:

Retain the black cap for later use.

5. Holding the pump at half arm’s length away from you, place the

protective tube sheath over the jagged end of the smoke tube

and aim the smoke tube tip away from you and other people in

the area.

CautIon: Prior to compressing the bulb, ensure the smoke tube

is aimed in the correct direction and at the correct

distance from the test subject.

6. Tell the test subject to tightly close his or her eyes.
7. Slowly, gently, and uniformly compress the bulb at a

controlled, steady rate until the bulb is completely compressed.