Operating Instructions

C. Instruct the test subject to minimize his or her exposure

to the smoke and keep his or her eyes tightly shut during

the test.

D. Instruct the test subject to immediately step away from

the smoke and into fresh, clear air in the event of any

exposure or response to irritant smoke.

E. Instruct the test subject to demonstrate the following:

I. The proper method for donning the respirator
II. The proper method for securing a snug respirator fit
III. The proper method for manually checking the

respirator fit

IV. Explain to the test subject that the test subject

should not participate in an Irritant Smoke Qualitative

Respirator Fit Test if the test subject:

a. Has a pre-existing respiratory, cardiovascular,

bronchial, or sinus medical condition.

b. Is under a physician’s care for a respiratory,

cardiovascular, or bronchial ailment; sinus,

nasal, or ear infection; or impaired immune

system; or asthma.

c. Is allergic to or hypersensitive to hydrogen chlo-

ride, stannic chloride, stannic oxide, stannic

dioxide, tin tetrachloride, tin compounds,

hydrochloric acid, or metal chloride or

chemicals in general.