Operating Instructions

C. The test subject is hypersensitive or allergic to

stannic chloride, stannic oxide, hydrogen chloride, tin

tetrachloride, tin compounds, or metal chloride.

D. The test subject has failed the medical evaluation specified

by OSHA 29 CFR 1910.134.

5. Do not perform or administer Irritant Smoke Qualitative

Respirator Fit Testing using the Nextteq Irritant Smoke Tube

Kit (P/N 9500), Gastec Smoke Tubes (P/N 9501), the Nextteq

Aspiration Bulb Pump (P/N 9502), or the Nextteq One-Way

Valve Aspiration Bulb Pump (P/N 90005) unless you are a fully

trained, qualified, and professional commercial, industrial,

military, or government test administrator experienced in

correctly conducting irritant smoke qualitative respirator fit

testing and fully trained and experienced in generating a small,

weak, dilute stream of smoke with an irritant smoke tube and

an aspiration bulb pump.

6. Use only in well-ventilated areas to prevent the buildup of

smoke or fumes. Do not use under a hood or other enclosed

area. Do not use in a confined space.

7. Irritant Smoke Qualitative Respirator Fit Testing should be

performed in strict compliance with OSHA 29 CFR 1910.134.

NIOSH-approved HEPA plus acid gas filters or equivalent

filters specified by NIOSH may be used in all fit testing in lieu

of HEPA filters.