Nextteq Irritant Smoke Tube Kit for Respirator Fit Testing and Airflow Indication User Manual

Page 42

Advertising
background image

Nextteq Irritant Smoke Tube Kit Manual

The Gastec Irritant Smoke Tube (Part Number 9501) is manufactured by the Gastec Corporation.

Nextteq is Gastec’s exclusive U.S. master wholesale distributor.

Page 39

Tel: 813-249-5888 Toll free: 877-312-2333 Fax: 813-249-0188 Toll free: 877-312-2444 www.nextteq.

P/N 9505 Rev F 8/09

E. Generate a small, weak, dilute stream of irritant smoke

that is the absolute minimum amount necessary to elicit

a response.

F. Perform the Sensitivity Check.
G. Recognize an invalid test.

7. Prior to commencing the Sensitivity Check:

A. The administrator shall ensure the test subject has

read, understands, and agrees to comply with all the

provisions of this test protocol; all of Gastec and Nextteq

specifications, instructions, and warnings; and the test

subject’s duties and responsibilities as described in

OSHA 29 CFR 1910.134.

B. The test subject shall be given a description of the

test, the test subject’s duties and responsibilities, and

instructed to minimize his or her exposure to the smoke

and to keep his or her eyes tightly shut during the test.

C. The test subject shall be instructed to immediately step

into fresh, clean air in the event of any exposure or

response to irritant smoke.

D. The test subject shall be given instructions in and shall

correctly demonstrate for an experienced, trained, and

qualified professional test administrator:
I.

The proper method to waft a small, weak, and diluted

concentration of smoke toward the test subject by

extending his or her arm at full length with the palm

up and fingers closed together. The test subject’s

hand should be extended to the edge of the smoke

cloud. If the test subject’s arm is not extended at

full length, the test subject shall back up until his or

Sensitivity Check Protocol