Sensitivity Check Protocol

CautIon: Prior to compressing the bulb, ensure the smoke

tube tip is 36 inches or more away from the test

subject’s face and NOT aimed in the direction of the

test subject’s face.

8. Slowly and gently compress the bulb at a controlled, uniform,

steady rate until a small, weak, dilute stream of irritant smoke

is produced that is the absolute minimum necessary to elicit a

response from the test subject being tested.

9. Immediately stop compressing the bulb and release

the partially compressed bulb. No additional smoke is to

be generated.

10. The test subject shall stand approximately 36 inches away from

the cloud of smoke.

11. The test subject shall extend his or her arm to the edge of the

smoke cloud with palm facing upward.

12. Keeping his or her eyes closed, the test subject shall gently

and slowly wave a small, dilute portion of the smoke toward

his or her breathing zone using the fingertips of his or her

outstretched hand.

13. Keeping his or her eyes closed, the test subject shall sample

a slight, weak, dilute whiff of smoke by taking a small, weak,

shallow, and short duration sniff of smoke.

14. The test subject shall then immediately step away from the

smoke into clean, fresh air.

15. The trained, qualified, professional test administrator shall

advise the test subject when the test subject is away from the

smoke. The administrator shall then instruct the test subject to

open his or her eyes.