Nextteq Irritant Smoke Tube Kit Manual

The Gastec Irritant Smoke Tube (Part Number 9501) is manufactured by the Gastec Corporation.

Nextteq is Gastec’s exclusive U.S. master wholesale distributor.

Tel: 813-249-5888 Toll free: 877-312-2333 Fax: 813-249-0188 Toll free: 877-312-2444 www.nextteq.
P/N 9505 Rev F 8/09

MSDS

V. MSdS
This MSDS is also available at www.nextteq.com as P/N 90040.

______________________________________________________

part 1 - Material Identification

______________________________________________________
Material name: Nextteq Irritant Smoke Tube Kit (using Gastec

Irritant Smoke Tubes) (P/N 9500)

Gastec Irritant Smoke Tubes (P/N 9501)

Chemical name: Stannic Chloride (CAS No. 7646-78-8, UN No.

1827)

Synonyms: A. Tin tetrachloride, Tin (IV) Chloride

B. Air Flow Indicator Tube

C. Irritant Smoke Generator

formula: SnCl

4

Chemical family: Metal Chloride

______________________________________________________

part 2 - Ingredients and hazards

______________________________________________________
Stannic chloride reacts with ambient humidity to liberate a white

smoke consisting of hydrogen chloride (HCl) and tin compounds.

The emitted smoke has a strong irritating odor.
exposure limits
Tin Inorganic Compounds

ACGIH-TLV: TWA 2 mg/m

3

OSHA PEL: 2 mg/m

3

Hydrogen Chloride

OSHA PEL: Ceiling 5 ppm

ACGIH-TLV: STEL Ceiling 2 ppm