Nextteq Irritant Smoke Tube Kit for Respirator Fit Testing and Airflow Indication User Manual

Page 25

Advertising
background image

Page 22

Nextteq Irritant Smoke Tube Kit Manual

The Gastec Irritant Smoke Tube (Part Number 9501) is manufactured by the Gastec Corporation.

Nextteq is Gastec’s exclusive U.S. master wholesale distributor.

Tel: 813-249-5888 Toll free: 877-312-2333 Fax: 813-249-0188 Toll free: 877-312-2444 www.nextteq.
P/N 9505 Rev F 8/09

MSDS

Get medical help in case of a large area of contact or if irritation

persists.
Inhalation: Remove test subject to fresh air. Restore and/or support

breathing as necessary. Provide oxygen therapy for persistent

coughing or if breathing is difficult. Keep subject warm and at rest.

Get medical help.
Swallowed: If swallowed, get medical help immediately.
aSSIStanCe: IF THE USER IS CONFUSED ABOUT THE PROPER

USE OF THE SMOKE TUBE / GENERATOR OR ANY INSTRUCTIONS,

WARNINGS, LABELS, OR THE MANUAL, PRIOR TO USING

THIS PRODUCT THE USER SHOULD CONTACT NEXTTEQ FOR

ASSISTANCE. NEXTTEQ CAN BE CONTACTED AT ONE OF THE

FOLLOWING TELEPHONE NUMBERS: TOLL FREE 877-312-2333 OR

LOCAL NUMBER 813-249-5888.

______________________________________________________

part 6 - reactivity Information

______________________________________________________
Stability: SnCl

4

decomposes upon exposure to moist air or

water. HCl is a stable compound. It does not undergo hazardous

polymerization; however, HCl can catalyze polymerization of other

compounds.
Conditions to avoid: Reacts with turpentine, alcohols, and amines

causing a potential fire hazard. Incompatible materials include alkali

compounds, amines, metal oxides, hydroxides, copper, brass, zinc,

other metals, turpentine, and alcohols. Mixing with alkali metals may

result in an explosion.
hazardous decomposition products: When heated to

decomposition, the smoke tubes will emit chloride fume.