Nextteq Irritant Smoke Tube Kit for Respirator Fit Testing and Airflow Indication User Manual

Page 7

Advertising
background image

Page 4

Nextteq Irritant Smoke Tube Kit Manual

The Gastec Irritant Smoke Tube (Part Number 9501) is manufactured by the Gastec Corporation.

Nextteq is Gastec’s exclusive U.S. master wholesale distributor.

Tel: 813-249-5888 Toll free: 877-312-2333 Fax: 813-249-0188 Toll free: 877-312-2444 www.nextteq.
P/N 9505 Rev F 8/09

II. SpeCIfICatIonS
aspiration bulb pump

Length:

3.386 in / 86 mm

Diameter:

1.693 in / 43 mm

Capacity:

30 cc

Operating Temperature:

32°F to 104°F / 0°C to 40°C

Operating Relative Humidity: 10% to 95% RH

Storage Temperature:

41°F to 77°F / 5°C to 25°C

Storage Condition:

Secure, dry, cool space away from

direct light

Smoke tubes

Length:

5.5 in / 139.7 mm

Diameter:

0.0113 in / 0.287 mm

Total Volume:

35 ml

Delivered Volume:

~ 30 ml

Active Ingredient:

Stannic Chloride (SnCl

4

)

Fluid Admitted:

Air

Generated Smoke Strokes:

Approximately 200 (depending on

humidity) *

Color of Generated Smoke: White

Operating Temperature:

32°F to 104°F / 0°C to 40°C

Operating Relative Humidity: 10% to 95% RH

Storage Temperature:

41°F to 77°F / 5°C to 25°C

Storage Condition:

Secure, dry, cool space away from

direct light

* At 20% or less relative humidity, the number of strokes capable of

generating smoke will increase by ~10%. At 80% relative humidity,

the number of strokes capable of generating smoke will decrease by

~10%.

Specifications