Nextteq Irritant Smoke Tube Kit Manual

The Gastec Irritant Smoke Tube (Part Number 9501) is manufactured by the Gastec Corporation.

Nextteq is Gastec’s exclusive U.S. master wholesale distributor.

Tel: 813-249-5888 Toll free: 877-312-2333 Fax: 813-249-0188 Toll free: 877-312-2444 www.nextteq.
P/N 9505 Rev F 8/09

Sensitivity Check Protocol

B. That the test subject’s eyes should be tightly closed before

he or she wafts the smoke in his or her direction.

C. That the test subject’s eyes should remain closed until the

test subject is free of the irritant smoke.

D. That the administrator shall advise the test subject when

the test subject is free of the smoke and it is safe for the

test subject to open his or her eyes.

C. test protocol

1. Wearing a pair of safety gloves and eye protection, break both

ends of the Gastec Irritant Smoke Tube by bending each end in

the tube tip breaker hole.

2. Place a black cap on one end of the smoke tube.

3. Pointing the tube end with the black cap away from you, insert

the tube into the Nextteq Aspiration Bulb Pump, being careful

not to compress the bulb.

4. Confirm you are using the correct aspiration bulb pump for the

Sensitivity Check.

5. Immediately before commencing the Sensitivity Check, remove

the black cap from the end of the tube.

note: Retain the black cap for later use.
6. Holding the pump at half arm’s length away from you, place

the protective tube sheath over the jagged end of the smoke

tube and aim the tip of the smoke tube away from you and the

test subject.

7. Tell the test subject to tightly close his or her eyes.