Connection to an external weather source, Bendix/king kdr-610 setup, Connection to an external weather source -12 – BendixKing AV8OR Ace - Users Guide User Manual

Page 406: Bendix/king kdr-610 setup -12, Figure 6-4: weather setup – kdr-610 -12

Advertising
background image

Honeywell Bendix/King AV8OR Ace User’s Guide

Appendix D200904000003
Page 6-12

Rev 3 Mar 2012

©

Honeywell International Inc. Do not copy without express permission of Honeywell

CONNECTION TO AN EXTERNAL WEATHER
SOURCE

Bendix/King KDR-610 Setup

To configure the AV8OR ACE to receive weather data from the
KDR-610, perform the following steps:

From the Aviation Main Menu, tap the

soft key to open the

System Setup Menu.

Highlight the

Device Setup

option and tap the

SELECT

soft key to

show the

Device and Port Setup

page.

On the Device and Port Setup page, the configuration steps are:

Decide whether to use the “

COM 1

” or “

COM 2

” serial port.

Make sure that the serial port you decide to use is not in use
by any other port on the Device Setup Page. If the serial port
is in use, the Port field that shows it must be changed to
another setting.

Set the Weather

Port

to “

COM 1

” or “

COM 2

.

Set the Weather

Type

to “

KDR-610

”. When finished the

Device and Port Setup page should look like the setup

options in the figure below.

Figure 6-4: Weather Setup – KDR-610

The output of the KDR 610 is RS 422. You must use an RS 422
to RS 232 converter to change the KDR 610 differential outputs
to the single ended levels that the AV8OR ACE requires. This
converter is installed between the KDR 610 and the AV8OR.