Estimated Time of Arrival for Next Leg Data Field

The

ETA LEG

data field displays the calculated arrival

time calculated as the distance to the next waypoint, divided by the
ground speed, plus the current time.

Estimated Time of Arrival Data Field

The estimated time of arrival data window displays the

calculated arrival time calculated as the distance to the destination
waypoint, divided by the ground speed, plus the current time.

Estimated Time En-Route for next Leg Data Field

The

ETE LEG

data field displays the calculated time en

route as the distance to the next waypoint, divided by the ground
speed. If the ETE is greater than 10 minutes then the format is
HH:MM. If HH is less than 10 then no leading zeroes show.
Otherwise the format is MM:SS, with leading zeroes displayed. If the
ETE is invalid or greater than 24 hours then “--:--“ shows.

Estimated Time En-Route Data Field

The estimated time en-route data window displays the

calculated time en route as the distance to the destination waypoint,
divided by the ground speed. If the ETE is greater than 10 minutes
then the format is HH:MM. If HH is less than 10 then no leading
zeroes are displayed. Otherwise the format is MM:SS, with leading
zeroes displayed. If the ETE is invalid or greater than 24 hours then
“--:--“ is displayed.