1 create an evc record – CANOGA PERKINS 9145ELB NID Software Version 4.01 User Manual

Page 120

Advertising
background image

9145ELB NID Software User’s Manual

Configuring EVC

EVC Configuration

110

10.2.1 Create an EVC Record

1. On the EVC Configuration screen (Figure 10-2), type 1 and press Enter. The EVC

Record List screen (Figure 10-3) opens.

Figure 10-3 EVC Record List screen

2. To create a new record, type A and press Enter. The Create A New EVC Configuration

Record (Figure 10-4) screen opens.

3. In the S-VLAN field, type an ID number and press Enter. The User Interface field is

highlighted.

4. In the User Interface field, press the Space bar to select a User Port and press Enter. The

Name field is highlighted.

5. In the Name field, type name for the record and press Enter. The Multiplexing Type field

is highlighted.

6. In the Multiplexing Type field, press the Space bar to select Service Multiplexing or All-to-

One and press Enter. The Administrative State field is highlighted.

7. In the Administrative State field, press the Space bar to select Up or Down. and press

Enter. The Statistics field is highlighted.

8. In the Statistics field, press the Space bar to select Disabled, S-VLAN, or C-VLAN and

press Enter. The S-Tag PCP Value field is highlighted.

9. In the S-Tag PCP Value field, press the Space bar to select Static, Copy from Ingress, or

Map from CVID, and press Enter.

10. In the Static/Default PCP Value field, specify a P-bits value between 0-7, and press Enter.

Canoga Perkins Corp. Ethernet 1G/10G Network Interface Device 29-AUG-2011
9145ELB-971-4-0 V04.01 10:55:13
-------------------------------EVC RECORD LIST---------------Items 1 - 5 of 5-
S-VLAN USER MUX NAME STATS OPERATIONAL
ID PORT TYPE STATE

XXXX/XXXX USR12 Service Mux 12345678901234567890123456789012 Disabled DOWN
C-VLANs (5): UTag, PTag, 20, 21, 22
30 USR1 All-to-One EVC 30 Disabled DOWN
C-VLANs (All)
40 10G2 Service Mux EVC 40 Disabled DOWN
C-VLANs (1): 40
1000 USR2 Service Mux EVC 100 Disabled DOWN
C-VLANs (20): 1000, 1001, 1002, 1003, 1004, 1005, 1006, 1007, 1008...
2000 USR2 Service Mux EVC 200 Disabled DOWN
C-VLANs (20): 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008...

Select [(F)irst, (P)rev, (N)ext, (L)ast, (A)dd, (D)elete, (E)dit,
(S)Traffic Statistics, (O) Policing Statistics,<R>eset All EVC Statistics]:

------------------------------------Messages-----------------------------------

Advertising