System Configuration

9145ELB NID Software User’s Manual

IP/SNMP Agent Configuration

17

3.1.2 Auxiliary IP Configuration

On the IP/SNMP Agent Configuration screen (Figure 3-4), type 2 and press Enter. The Auxiliary
IP Configuration screen (Figure 3-6) opens.

The Auxiliary IP is an additional IP address that is provided for testing and connectivity only. It
allows the 9145ELB to be PINGed without allowing Telnet or Management access that could be
disruptive. The Auxiliary IP rate is limited to 500 pings per second. This allows connectivity and
rudimentary performance testing from subscriber/user VLANs without compromising network
security.

To configure the parameters, type the corresponding number and press Enter. Enter data or
press the Space bar to view the configuration choices for the parameters described below.

Separate tagging configuration is necessary for User Side and Network side ports. All ports on
the user side must share the same tagging configuration.

Figure 3-6 Auxiliary IP Configuration screen

1. Auxiliary IP Address Sets the 9145ELB Auxiliary IP Address.

Auxiliary Subnet Mask Sets the 9145ELB Auxiliary IP Subnet Mask.

2. Inband Auxiliary Port Describes the Auxiliary IP address ports.

If the 10G2 port is configured as a Network Port, then options are User1 Port Only
through User16 Port Only, Network Port, and No Ports Allowed.

If the 10G2 port is configured as a User Port, then options are User1 Port Only
through User8 Port Only, Network Port, 10G2 Port Only, and No Ports Allowed.

3. Auxiliary VLAN Tagging on Network ports Describes the tagging mode for the frames

sent and received when the Auxiliary IP address is configured on the Network Port.


Canoga Perkins Corp. Ethernet 1G/10G Network Interface Device 29-AUG-2011
Model 9145ELB-B83-0 V04.01 10:55:13
------------------------------AUXILIARY IP CONFIGURATION-----------------------

1) Auxiliary IP Address 010.0012.013.014
Auxiliary Subnet Mask 255.255.255.000
2) Auxiliary Port 10G1 Port Only
3) Aux VLAN Tagging on Network ports S-T-C Tagged
4) Aux C-VLAN ID on Network ports 100
5) Aux T-VLAN ID on Network Ports 200
6) Aux S-VLAN ID on Network ports 300
7) Aux VLAN Tagging on User ports Untagged
8) Aux C-VLAN ID on User ports 1000
9) Allow Any Vlan Disabled
10) Aux IP Rate Limiting Enabled

Select [1-10]:

------------------------------------Messages-----------------------------------