Carrying out kinematic and stop & go measurements – Leica Geosystems GPS System 500 - Getting Started with Static and Kinematic Surveys User Manual

Page 39

Advertising
background image

39

Static and Kinematic Surveys-2.0.0en

Kinematic and Stop & Go surveying

6
7
8
9
13
23
29
33
34

37

Carrying out Kinematic and Stop & Go measurements

Step 2:

Starting the rover sensor

Kinematic and Stop & Go surveys are

part of the "Survey" operation of

System 500, to be found under

"1 Survey" in the Main menu.

• Select a suitable configuration set,

preferably the factory default set

"PP_KIS".

Of importance is that the data logging

parameters are set correctly for

Kinematic and Stop & Go surveys.

Logging for both static and moving

observations must be turned on. Also

the parameter "Static Initialization"

has to be set to "YES" :

Step 1:

Setting up the reference site

Follow the instructions given in the

previous chapters on running a static

survey.

Make sure the "observation rate" is

the same as the one you choose for

the roving sensor and that logging of

static data is turned on. Normally a

rate of 2, 3 or 5 seconds is chosen

for Kinematic and Stop & Go surveys.

Make sure that the reference receiver

is operated in an environment which

is suitable for GPS measurements; it

should be free of obstructions in

order to avoid missing satellites or

poor satellite signal reception.